Mosquito Magnet® Liberty

The Net is not installed properly

Fault - Red On, Yellow off, Green Flashing
Red On, Yellow off, Green Flashing

This error indicates that the Net is not installed properly or needs to be replaced. NOTE: This error applies to models made 2003 and beyond only. Newer Mosquito Magnet® Liberty models do not have this feature.

How to fix if net is not installed properly.
  1. Shut off trap and unplug from the wall outlet.
  2. Open clear door by turning the handle a quarter turn clockwise.
  3. Remove the Net.
  4. There is a small switch that looks like a roller on the outside of the opening where you slide the Net into place.
    Net switch
  5. When you slide the Net down on to the holder the Tab on the Net frame must hit the Net switch.

    Net switch tab
  6. If you have tried this several times and still get the same fault, you may need to replace the Net.

To get replacement Nets

Check out our Online Store or Call our Dedicated Customer Support.

Do not return your product to the store. Our 360° Customer Support Network is ready to help you! Call 800-214-7721 and let our Dedicated Customer Support help you "Take Back Your Yard!".